Supported content
WWPG 0.2.0 retains 164 base behavior groups, or 165 with optional Pinout. All 11 built-in CEE panel attachments and all 28 built-in PG board components are included. The base jar starts without either optional mod. Native cosmetic variants, ingredients, assembly parts and deferred moving content are accounted for in the registry inventory.
The beta.5 native support matrix and registry inventory remain the inherited content baseline. The 0.2.0 verification record checks that baseline against the exact new runtime and worlds, alongside the extension fixtures. Historical support matrices and acceptance claims are not expanded retroactively.
Players can generate, store, transform, convert, measure and control mixed power; run native loads; edit and reuse board designs; assemble equipment; and repair bulbs, fuses and wiring. Structural parts keep their native assembly roles and do not gain invented terminals. Every claimed behavior maps to a working station or native assembly/repair workflow in the stationary yard; inventory cabinets do not establish coverage.
Extension API 1.0.0
Section titled “Extension API 1.0.0”The public API covers a stationary machine or assembly’s stable terminals, internal nodes and distinct elements, including parallel branches. Supported models include loads, switches, DC and AC sources, capacitors, inductors, diodes, transformers and controlled sources. Add-ons receive explicit valid or unavailable readings and own their native gameplay, rendering, synchronization and saved state.
Custom CEE properties use the separate CEE API; existing built-in properties are not replaced. PG add-ons use PG’s native component and terminal integration, with no second WWPG electrical owner. The contract defines the supported signatures and boundaries. The API Workshop demonstrates nine general machine models, a custom CEE panel indicator and a native PG board component. These examples do not inflate the inherited native behavior count.
Native items and workflows
Section titled “Native items and workflows”PG wires, hanging wires and cords, all 57 ordinary CEE wire variants and native duplex cables keep their native lengths, costs, orientation, rendering and cutting. Native PG banners/dampers and lineman-stick interactions are covered. PG’s multimeter reads voltage at either mod’s accessible terminals and current on either wire system; CEE’s clamp meter reads either wire system. Tool instructions explain the native limits, including glass insulation and creative-only duplex placement in the pinned CEE release.
The saved design workflow includes editing, saving, cold restart, reopening, native copying, assembly, placing and powering a board. Native item copies create fresh component identities; installed designs retain their identities across edits and reloads.
With CC;CPG: Pinout 0.2.1 and CC:Tweaked 1.120.2, computers switch all eight pins and read independently checked signed voltages. Lua common pin 9 maps to PG terminal 0; controlled pins 1–8 retain their numbering. Both wire systems, meters, supplies, panel inputs and board outputs are exercised, including computer restart and peripheral replacement. No replacement Lua API or required adapter block is introduced.
Behavior IDs
Section titled “Behavior IDs”These native registry IDs are useful to maintainers; the matrix distinguishes registry types and groups cosmetic variants. Structural parts appear with their checked assembly workflow.
| Category | Native behavior IDs |
|---|---|
| computer_control | pinout:pinout |
| controls | electroenergetics:broken_fuse, electroenergetics:cut_off_switch, electroenergetics:double_switch, electroenergetics:emergency_stop_button, electroenergetics:fuse, electroenergetics:fuse_holder, electroenergetics:high_voltage_switch, electroenergetics:momentary_switch, electroenergetics:potentiometer, electroenergetics:redstone_potentiometer, electroenergetics:redstone_relay, electroenergetics:relay, electroenergetics:sulfur_hexafluoride_breaker, powergrid:carbon_pile, powergrid:carbon_pile_coil, powergrid:contactor, powergrid:fuse_holder, powergrid:hv_breaker, powergrid:hv_switch, powergrid:lv_button, powergrid:lv_switch, powergrid:mv_switch, powergrid:punch_card_reader, powergrid:redstone_converter, powergrid:rheostat |
| conversion | electroenergetics:converter, powergrid:fe_inverter |
| electronics | electroenergetics:ammeter, electroenergetics:analog_lever, electroenergetics:cut_off_switch, electroenergetics:diode, electroenergetics:electrical_panel, electroenergetics:emergency_stop_button, electroenergetics:energy_meter, electroenergetics:indicator_bulb, electroenergetics:miniature_circuit_breaker, electroenergetics:momentary_switch, electroenergetics:steering_wheel, electroenergetics:tri_polar_energy_meter, electroenergetics:voltmeter, powergrid:barretter_tube, powergrid:bjt_npn, powergrid:bjt_pnp, powergrid:button, powergrid:capacitor, powergrid:circuit_board, powergrid:circuit_design_table, powergrid:connector, powergrid:current_gauge, powergrid:diode, powergrid:display_module, powergrid:fuse_holder, powergrid:inductor, powergrid:label, powergrid:light_bulb, powergrid:modular_display, powergrid:neon_bulb, powergrid:pentode, powergrid:potentiometer, powergrid:redstone_relay, powergrid:regulator_tube, powergrid:relay, powergrid:relay_dpdt, powergrid:resistor, powergrid:switch, powergrid:thyratron, powergrid:triode, powergrid:varistor, powergrid:vfet, powergrid:via, powergrid:voltage_gauge |
| instruments | powergrid:crt, powergrid:thermometer |
| loads | electroenergetics:broken_bulb, electroenergetics:bulb, electroenergetics:buzzer, electroenergetics:creative_resistor, electroenergetics:electric_pump, electroenergetics:indicator_bulb, electroenergetics:resistive_heater, electroenergetics:resistor, electroenergetics:white_electric_motor, powergrid:alarm_bell, powergrid:basin_heater, powergrid:ceiling_tile_lamp, powergrid:constant_speed_motor, powergrid:creative_resistor, powergrid:electric_fan, powergrid:electric_motor, powergrid:electric_pump, powergrid:electromagnet, powergrid:factory_light, powergrid:factory_light_light, powergrid:heating_coil, powergrid:light_fixture, powergrid:power_resistor, powergrid:servo, powergrid:string_light_block |
| meters | electroenergetics:ammeter, electroenergetics:current_transformer, electroenergetics:energy_meter, electroenergetics:frequency_meter, electroenergetics:synchroscope, electroenergetics:tri_polar_energy_meter, electroenergetics:voltmeter, powergrid:current_gauge, powergrid:energy_meter, powergrid:plotter, powergrid:power_gauge, powergrid:voltage_gauge |
| protection | powergrid:spark_gap |
| sources | electroenergetics:alternator_brushes, electroenergetics:alternator_rotor, electroenergetics:creative_battery, electroenergetics:radiator_panel, electroenergetics:stator, electroenergetics:three_phase_alternator_brushes, electroenergetics:voltage_regulator, powergrid:ceiling_tile_solar, powergrid:creative_current_source, powergrid:creative_voltage_source, powergrid:generator_clutch, powergrid:generator_commutator, powergrid:generator_housing, powergrid:generator_induction_rotor, powergrid:generator_large_induction_rotor, powergrid:generator_vertical_commutator, powergrid:solar_panel, powergrid:vertical_generator_housing, powergrid:winding |
| storage | electroenergetics:accumulator, electroenergetics:capacitor, electroenergetics:high_voltage_capacitor, electroenergetics:inductor, powergrid:battery, powergrid:portable_battery, powergrid:potato_battery |
| transformers | electroenergetics:redstone_variac, electroenergetics:transformer, electroenergetics:transformer_core, electroenergetics:variac, powergrid:nether_transformer, powergrid:transformer_core, powergrid:transformer_medium, powergrid:transformer_small, powergrid:variac |
| wiring | electroenergetics:catenary_holder, electroenergetics:concrete_pole, electroenergetics:connector, electroenergetics:double_connector, electroenergetics:duplex_wire_termination, electroenergetics:ground_rod, electroenergetics:insulator, electroenergetics:pole_mount, electroenergetics:quad_connector, electroenergetics:triple_connector, powergrid:ceiling_tile_connector, powergrid:ceiling_tile_junction, powergrid:cord_junction, powergrid:device_connector, powergrid:grounding_rod, powergrid:heavy_wire_connector, powergrid:socket, powergrid:wire_connector |
Boundaries
Section titled “Boundaries”The release validates the declared pinned stationary workflows and reference conditions, rather than every possible device configuration. Native source quirks, portable-battery charging behavior and potato-battery depletion remain upstream behavior; see installation notes.
Moving systems, altitude/velocity sensors, Sable sublevels, other optional integrations, broad version ranges, large-server benchmarks, asynchronous solving, advanced topology reduction and broader numerical extension points remain later milestones. Unknown constructs are diagnosed and isolated. The long-term specification retains those future requirements.
Published beta.1–beta.5 artifacts, support claims and evidence remain unchanged. Current status preserves historical investigations without assigning causes that their logs cannot prove.