Skip to content
Browse docs

Search documentation

Release 0.1.0-beta.5

Enter a topic to search.

    WWPG / 0.1.0-beta.5 / ARCHIVED

    Supported content

    WWPG 0.1.0-beta.5 covers 164 base behavior groups, or 165 with optional Pinout. All 11 built-in CEE panel attachments and all 28 built-in PG board components are included. The base jar starts without either optional mod. Native cosmetic variants, ingredients, assembly parts and deferred moving content are accounted for in the registry inventory.

    The verified support matrix links each in-scope behavior to its fixtures. The final verification record certifies the exact jar and worlds. The earlier candidate checklist remains unchanged as an input record; beta.4’s historical matrix is not expanded retroactively.

    Players can generate, store, transform, convert, measure and control mixed power; run native loads; edit and reuse board designs; assemble equipment; and repair bulbs, fuses and wiring. Structural parts keep their native assembly roles and do not gain invented terminals. Every claimed behavior maps to a working station or native assembly/repair workflow in the stationary yard; inventory cabinets do not establish coverage.

    PG wires, hanging wires and cords, all 57 ordinary CEE wire variants and native duplex cables keep their native lengths, costs, orientation, rendering and cutting. Native PG banners/dampers and lineman-stick interactions are covered. PG’s multimeter reads voltage at either mod’s accessible terminals and current on either wire system; CEE’s clamp meter reads either wire system. Tool instructions explain the native limits, including glass insulation and creative-only duplex placement in the pinned CEE release.

    The saved design workflow includes editing, saving, cold restart, reopening, native copying, assembly, placing and powering a board. Native item copies create fresh component identities; installed designs retain their identities across edits and reloads.

    With CC;CPG: Pinout 0.2.1 and CC:Tweaked 1.120.2, computers switch all eight pins and read independently checked signed voltages. Lua common pin 9 maps to PG terminal 0; controlled pins 1–8 retain their numbering. Both wire systems, meters, supplies, panel inputs and board outputs are exercised, including computer restart and peripheral replacement. No replacement Lua API or required adapter block is introduced.

    These native registry IDs are useful to maintainers; the matrix distinguishes registry types and groups cosmetic variants. Structural parts appear with their checked assembly workflow.

    Category Native behavior IDs
    computer_control pinout:pinout
    controls electroenergetics:broken_fuse, electroenergetics:cut_off_switch, electroenergetics:double_switch, electroenergetics:emergency_stop_button, electroenergetics:fuse, electroenergetics:fuse_holder, electroenergetics:high_voltage_switch, electroenergetics:momentary_switch, electroenergetics:potentiometer, electroenergetics:redstone_potentiometer, electroenergetics:redstone_relay, electroenergetics:relay, electroenergetics:sulfur_hexafluoride_breaker, powergrid:carbon_pile, powergrid:carbon_pile_coil, powergrid:contactor, powergrid:fuse_holder, powergrid:hv_breaker, powergrid:hv_switch, powergrid:lv_button, powergrid:lv_switch, powergrid:mv_switch, powergrid:punch_card_reader, powergrid:redstone_converter, powergrid:rheostat
    conversion electroenergetics:converter, powergrid:fe_inverter
    electronics electroenergetics:ammeter, electroenergetics:analog_lever, electroenergetics:cut_off_switch, electroenergetics:diode, electroenergetics:electrical_panel, electroenergetics:emergency_stop_button, electroenergetics:energy_meter, electroenergetics:indicator_bulb, electroenergetics:miniature_circuit_breaker, electroenergetics:momentary_switch, electroenergetics:steering_wheel, electroenergetics:tri_polar_energy_meter, electroenergetics:voltmeter, powergrid:barretter_tube, powergrid:bjt_npn, powergrid:bjt_pnp, powergrid:button, powergrid:capacitor, powergrid:circuit_board, powergrid:circuit_design_table, powergrid:connector, powergrid:current_gauge, powergrid:diode, powergrid:display_module, powergrid:fuse_holder, powergrid:inductor, powergrid:label, powergrid:light_bulb, powergrid:modular_display, powergrid:neon_bulb, powergrid:pentode, powergrid:potentiometer, powergrid:redstone_relay, powergrid:regulator_tube, powergrid:relay, powergrid:relay_dpdt, powergrid:resistor, powergrid:switch, powergrid:thyratron, powergrid:triode, powergrid:varistor, powergrid:vfet, powergrid:via, powergrid:voltage_gauge
    instruments powergrid:crt, powergrid:thermometer
    loads electroenergetics:broken_bulb, electroenergetics:bulb, electroenergetics:buzzer, electroenergetics:creative_resistor, electroenergetics:electric_pump, electroenergetics:indicator_bulb, electroenergetics:resistive_heater, electroenergetics:resistor, electroenergetics:white_electric_motor, powergrid:alarm_bell, powergrid:basin_heater, powergrid:ceiling_tile_lamp, powergrid:constant_speed_motor, powergrid:creative_resistor, powergrid:electric_fan, powergrid:electric_motor, powergrid:electric_pump, powergrid:electromagnet, powergrid:factory_light, powergrid:factory_light_light, powergrid:heating_coil, powergrid:light_fixture, powergrid:power_resistor, powergrid:servo, powergrid:string_light_block
    meters electroenergetics:ammeter, electroenergetics:current_transformer, electroenergetics:energy_meter, electroenergetics:frequency_meter, electroenergetics:synchroscope, electroenergetics:tri_polar_energy_meter, electroenergetics:voltmeter, powergrid:current_gauge, powergrid:energy_meter, powergrid:plotter, powergrid:power_gauge, powergrid:voltage_gauge
    protection powergrid:spark_gap
    sources electroenergetics:alternator_brushes, electroenergetics:alternator_rotor, electroenergetics:creative_battery, electroenergetics:radiator_panel, electroenergetics:stator, electroenergetics:three_phase_alternator_brushes, electroenergetics:voltage_regulator, powergrid:ceiling_tile_solar, powergrid:creative_current_source, powergrid:creative_voltage_source, powergrid:generator_clutch, powergrid:generator_commutator, powergrid:generator_housing, powergrid:generator_induction_rotor, powergrid:generator_large_induction_rotor, powergrid:generator_vertical_commutator, powergrid:solar_panel, powergrid:vertical_generator_housing, powergrid:winding
    storage electroenergetics:accumulator, electroenergetics:capacitor, electroenergetics:high_voltage_capacitor, electroenergetics:inductor, powergrid:battery, powergrid:portable_battery, powergrid:potato_battery
    transformers electroenergetics:redstone_variac, electroenergetics:transformer, electroenergetics:transformer_core, electroenergetics:variac, powergrid:nether_transformer, powergrid:transformer_core, powergrid:transformer_medium, powergrid:transformer_small, powergrid:variac
    wiring electroenergetics:catenary_holder, electroenergetics:concrete_pole, electroenergetics:connector, electroenergetics:double_connector, electroenergetics:duplex_wire_termination, electroenergetics:ground_rod, electroenergetics:insulator, electroenergetics:pole_mount, electroenergetics:quad_connector, electroenergetics:triple_connector, powergrid:ceiling_tile_connector, powergrid:ceiling_tile_junction, powergrid:cord_junction, powergrid:device_connector, powergrid:grounding_rod, powergrid:heavy_wire_connector, powergrid:socket, powergrid:wire_connector

    The release validates the declared pinned stationary workflows and reference conditions, rather than every possible device configuration. Native source quirks, portable-battery charging behavior and potato-battery depletion remain upstream behavior; see installation notes.

    Moving systems, altitude/velocity sensors, Sable sublevels, other optional integrations, broad version ranges, large-server benchmarks, asynchronous solving, advanced topology reduction and a public extension API remain later milestones. Unknown constructs are diagnosed and isolated. The long-term specification retains those future requirements.

    Published beta.1–beta.4 artifacts, support claims and evidence remain unchanged. Current status preserves historical investigations without assigning causes that their logs cannot prove.

    Release-pinned source