Diagnostics and troubleshooting
Start with a small circuit and the pinned dependencies. Keep a world backup before upgrading or making destructive changes.
The circuit reads zero
Section titled “The circuit reads zero”- Compare your mod versions and PG solver settings with installation.
- Check the native feed switch, source, load, and complete return path.
- Measure accessible terminals with PG’s multimeter. Use its wire selection for current; use CEE’s clamp meter on a wire rather than a terminal.
- Compare the result with a known yard exhibit. Glass insulation carries essentially no power in the pinned CEE release; that exhibit’s dark lamp is expected.
- Ask an operator to check device mapping, loading state, and recent errors.
Operator diagnostics
Section titled “Operator diagnostics”These commands require permission level 2.
| Command | Use |
|---|---|
/wwpg |
Inspect mapping counts, simulation steps, and actual backend use. |
/wwpg errors |
Read recent timestamped compatibility errors. |
/wwpg topology |
Inspect recent structural changes and device identities. |
/wwpg at x y z |
Inspect a mapped block’s terminals, voltage, backend, and isolation state. |
Diagnostic queries do not load distant chunks or create electrical adapters.
Computer or pin readings look wrong
Section titled “Computer or pin readings look wrong”Check both optional mods, the peripheral beside the computer, and the native pin layout. Common is Lua pin 9, corresponding to PG terminal 0. Signed readings depend on which terminal is the voltage reference; a negative reading alone does not indicate a fault.
Updating and reporting a problem
Section titled “Updating and reporting a problem”Stop the game and server, back up the world, and replace the WWPG jar on every client and the server. Keep one WWPG jar in mods. Follow the release’s dependency requirements. Updating cannot recover wires or charge already lost and saved by an older version.
When opening an issue, include the mod versions, operating system, actual solver backend, relevant configuration, logs, and steps that reproduce the result. For a yard report, include the exhibit code, action, expected reading, and observed result.
Beta.5 repairs several reproduced persistence and lifecycle problems. Earlier intermittent failures remain in the release-pinned status record where their original cause was not established. Passing current checks do not certify every configuration or large-server performance.